Hydrazine Analyzer
Quantichem® 9071C
The Waltron Quantichem® 9071C Hydrazine Analyzer is the most advanced hydrazine instrument specifically developed for use in continuous measurement and determination of hydrazine concentration in boiler feedwater.
Common Hydrazine Analyzer application points in a boiler system for online hydrazine measurement include: deaerator, condensate system and boiler feedwater.
Download Hydrazine Analyzer 9071C brochure (PDF)
|
|
|
| FEATURES |
|
BENEFITS |
 |
 |
 |
 |
| Wide analysis range: 0.01ppb – 1ppm |
|
Low reagent and standard consumption |
 |
 |
 |
| Low maintenance |
|
Minimal maintenance required |
 |
 |
 |
| Very low reagent and standard consumption to be changed only every two months |
|
Automatic operation |
 |
 |
 |
| No change of diffusion tubing |
|
|
 |
 |
 |
| Automatic range selection |
|
|
 |
 |
 |
| Process calibration – calibrate to sample |
|
|
 |
 |
 |
| Two 4-20 mA isolated current outputs |
|
|
 |
 |
 |
| Protection of sensor from “Hot Sample” |
|
|
 |
 |
 |
| Automatic temperature compensation |
|
|
 |
 |
 |
| Automatically stores last 10 calibrations and alarm logs |
|
|
 |
 |
 |
| Rechargeable hydrazine cell |
|
|
 |
 |
 |
|
Quantichem® 9071C Sensor Unit
During calibration the 3-way valve is activated, a standard of known hydrazine concentration passes through a heat exchanger to equilibrate the solution’s temperature to that of the sample. The standard then enters the constant head unit where flow is stabilized. Alkaline buffer vapor is added via a vapor entrainment mechanism before the standard enters the hydrazine cell and flows to drain. During normal operating conditions the standard solution is replaced by the sample. |
 |
Flow path during calibration mode and normal operating conditions
 |
 |
 |
| |
| |
| Operating
Conditions |
 |
 |
 |
| Sample |
|
Temperature: 41 – 131° F (5 – 55° C); Flow 150 – 400 ml/min |
 |
 |
 |
| Ambient
Temperature |
|
32 – 131° F (0 – 55° C) |
 |
 |
 |
| Pressure |
|
5 – 30 psig (0.35 – 2.07 bar) |
 |
 |
 |
| Composition |
|
Sample should be filtered to 60 microns, free of film forming compounds |
 |
 |
 |
| |
| |
| Mechanical |
 |
 |
 |
| Construction |
|
Transmitter – high strength ABS,IP65 (NEMA 4x)
Wet section – high strength ABS and sheet metal,all wetted parts stainless steel or PVC, IP55 (NEMA 4) |
 |
 |
 |
| Dimensions |
|
Transmitter:Height = 10.92” (27.74 cm), Width = 7” (17.78 cm), Depth = 3.54” (8.99 cm)
Wet Section:Height = 18.25” (46.36 cm) including drain, Width = 11.25”(28.58 cm),Depth=7.63”(19.38 cm) |
 |
 |
 |
| Mounting |
|
Four key-style holes: Height = 0.86” (2.18 cm), Top Width = 0.281” (0.714 cm), Radius = 0.28” (0.711 cm) Horizontal:9” (22.86 cm), Vertical:12.875” (32.70 cm) |
 |
 |
 |
| Weight |
|
23 lbs. (10.44 kg) |
 |
 |
 |
| Wiring |
|
Eight (8) conduit knockouts |
 |
 |
 |
| Piping |
|
Sample Inlet: 1/4" (0.635 cm) OD Swagelokt®, Drain:3/8" (0.953 cm) OD tube |
 |
 |
 |
| Distance |
|
Up to 325 feet (100 meters) on request |
 |
 |
 |
| Finish |
|
Corrosion resistant |
|
|