Spare
Parts
Reagents
Manuals
MSDS
Sheets
Troubleshooting
Shopping Cart
To
order this complete analyzer, please call our sales office at
(800) 242-7353 |
|
|
QUANTICHEM®
9001 COMPACT SERIES
Sodium Analyzer
Quantichem® 9031C
The Waltron Quantichem® 9031C Sodium Analyzer is the most advanced online instrument specifically developed for use in continuous measurement and determination of sodium ion concentration.
Common 9031C Sodium Analyzer application points in a boiler system for online sodium measurement include:make-up water,condensate,boiler feedwater and saturated steam/main steam.
Download 9031C Sodium Analyzer brochure (PDF)
|
|
|
| FEATURES |
|
BENEFITS |
 |
 |
 |
 |
| • Wide analysis range: 0.01ppb – 10ppm |
|
• Low reagent and standard consumption |
 |
 |
 |
| • Low maintenance |
|
• Minimal maintenance required |
 |
 |
 |
| • Very low reagent and standard consumption |
|
• Automatic operation |
 |
 |
 |
| • No change of diffusion tubing |
|
|
 |
 |
 |
| • Automatic range selection |
|
|
 |
 |
 |
| • Process calibration – calibrate to sample |
|
|
 |
 |
 |
| • Two 4-20 mA isolated current outputs |
|
|
 |
 |
 |
| • Protection of electrodes from “Hot Sample” |
|
|
 |
 |
 |
| • Automatic temperaturecompensation |
|
|
 |
 |
 |
| • Automatically stores last 10 calibrations and alarm logs |
|
|
 |
 |
 |
| • No use of highly toxic reagents such as monoethylamine or diisopropylamine |
|
|
 |
 |
 |
Flow path during calibration mode and normal operating conditions

Quantichem® 9031 Sensor Unit
During calibration the 3-way valve is activated, a standard of known sodium concentration passes through a heat exchanger to equilibrate the solution’s temperature to that of the sample. The standard then enters the constant head unit where flow is stabilized. Alkaline buffer vapor is added via a vapor entrainment mechanism before the standard enters the sodium measuring flow cell and flows to drain. During normal operating conditions the standard solution is replaced by the sample.
| |
| |
| Mechanical |
 |
 |
 |
| Construction |
|
Transmitter – high strength ABS,IP65 (NEMA 4x)
Wet section – high strength ABS and sheet metal,all wetted parts stainless steel or PVC,IP55 (NEMA 4) |
 |
 |
 |
| Dimensions |
|
Transmitter: Height = 10.92” (27.74 cm), Width = 7” (17.78 cm), Depth = 3.54” (8.99 cm)
Wet Section: Height = 18.25“ (46.36 cm) including drain, Width = 11.25” (28.58 cm), Depth = 7.63” (19.38 cm) |
 |
 |
 |
| Mounting |
|
Four key-style holes: Height = 0.86” (2.18 cm), Top Width = 0.281” (0.714 cm), Radius = 0.28” (0.711 cm) Horizontal: 9” (22.86 cm), Vertical: 12.875” (32.70 cm) |
 |
 |
 |
| Weight |
|
23 lbs. (10.44 kg) |
 |
 |
 |
| Wiring |
|
Eight (8) conduit knockouts |
 |
 |
 |
| Piping |
|
Sample Inlet: 1/4” (0.635 cm) OD Swagelokt, Drain: 3/8” (0.953 cm) OD tube |
 |
 |
 |
| Distance |
|
Up to 325 feet (100 meters) on request |
 |
 |
 |
| Finish |
|
Corrosion resistant |
|
|