corporateproductsnewscontact us
DeutchPolishFrench
 
 
   
back
 
       
 

9031C Sodium Analyzer spare parts Spare Parts
9031C Sodium Analyzer reagents Reagents
9031C Sodium Analyzer manuals Manuals
9031C Sodium Analyzer msds sheets MSDS Sheets
9031C Sodium Analyzer troubleshooting Troubleshooting

Shopping Cart

To order this complete analyzer, please call our sales office at
(800) 242-7353
 
 
Send me more information about the 9031C Sodium Analyzer.  
QUANTICHEM® 9001 COMPACT SERIES

Sodium Analyzer
Quantichem® 9031C

The Waltron Quantichem® 9031C Sodium Analyzer is the most advanced online instrument specifically developed for use in continuous measurement and determination of sodium ion concentration.

Common 9031C Sodium Analyzer application points in a boiler system for online sodium measurement include:make-up water,condensate,boiler feedwater and saturated steam/main steam.

Download 9031C Sodium Analyzer brochure (PDF)

 

Waltron Quantichem® 9031C Sodium Analyzer

Please contact us
for panel mount version.

 
FEATURES    BENEFITS
• Wide analysis range: 0.01ppb – 10ppm   • Low reagent and standard consumption
• Low maintenance   • Minimal maintenance required
• Very low reagent and standard consumption   • Automatic operation
• No change of diffusion tubing    
• Automatic range selection    
• Process calibration – calibrate to sample    
• Two 4-20 mA isolated current outputs    
• Protection of electrodes from “Hot Sample”    
• Automatic temperaturecompensation    
• Automatically stores last 10 calibrations and alarm logs    
• No use of highly toxic reagents such as monoethylamine or diisopropylamine    

Flow path during calibration mode and normal operating conditions

9031C Sodium Analyzer - flow path during calibration mode and normal operating conditions

Quantichem® 9031 Sensor Unit
During calibration the 3-way valve is activated, a standard of known sodium concentration passes through a heat exchanger to equilibrate the solution’s temperature to that of the sample. The standard then enters the constant head unit where flow is stabilized. Alkaline buffer vapor is added via a vapor entrainment mechanism before the standard enters the sodium measuring flow cell and flows to drain. During normal operating conditions the standard solution is replaced by the sample.  
 

GENERAL SPECIFICATIONS
Performance
Range   0.01ppb - 10ppm
Accuracy  

±5% of reading or ±0.1ppb (whichever is greater) within ±5°C of calibration temperature

Reproducibility   ±5% of reading or ±0.1ppb (whichever is greater) at constant temperature
Response Time  

90% of 1-10ppb step: less than 4 minutes; 90% of 100-1ppb step: less than 6 minutes

Temperature Compensation   Automatic

pH Compensation

 

Alkaline vapor buffer:0.88 SG (28% to 30% NH3) ammonia above 0.1 ppb sodium,50% diethylamine solu-tion below 0.1ppb sodium

Single or 2-point Calibration  

Manual calibration

Current Outputs   Two isolated 4-20mA current (analog) outputs
Digital Outputs  

Communication interface via RS-232 & RS-485 using MODBUS RTU protocol

Alarms  

Three voltage-free contacts, alarm points set from transmitter rated at 2A, 250VAC (non-inductive)

Power   Wide range of input power supply 90VAC – 250VAC
CECertification (on request)  

Meets low voltage and low electromagnetic compatibility directives

 
 
Operating Conditions
Sample   Temperature: 41 – 131° F (5 – 55°C); Flow 150 – 400 ml/min
Ambient Temperature   32 – 131°F (0 – 55°C)
Pressure   5 – 30 psig (0.35 – 2.07 bar)
Composition   Sample should be filtered to 60 microns,free of film forming compounds
 
 
Mechanical
Construction   Transmitter – high strength ABS,IP65 (NEMA 4x)
Wet section – high strength ABS and sheet metal,all wetted parts stainless steel or PVC,IP55 (NEMA 4)
Dimensions  

Transmitter: Height = 10.92” (27.74 cm), Width = 7” (17.78 cm), Depth = 3.54” (8.99 cm)
Wet Section: Height = 18.25“ (46.36 cm) including drain, Width = 11.25” (28.58 cm), Depth = 7.63” (19.38 cm)

Mounting   Four key-style holes: Height = 0.86” (2.18 cm), Top Width = 0.281” (0.714 cm), Radius = 0.28” (0.711 cm) Horizontal: 9” (22.86 cm), Vertical: 12.875” (32.70 cm)
Weight   23 lbs. (10.44 kg)
Wiring   Eight (8) conduit knockouts
Piping  

Sample Inlet: 1/4” (0.635 cm) OD Swagelokt, Drain: 3/8” (0.953 cm) OD tube

Distance   Up to 325 feet (100 meters) on request
Finish   Corrosion resistant
 
       

 

corporate | products | service programs | news | contact us | shopping cart | home | sitemap