| FEATURES |
|
BENEFITS |
 |
| Sensing
System Flexibility |
|
Operator
can choose four sensor cell systems utilizing flowthru or dip configurations
for a wide range of applications. |
 |
 |
 |
| Comprehensive
Self-Diagnostics |
|
Ensures
measurement accuracy by automatically checking sensor performance and ensuring
that the light source is operating within the specification. |
 |
 |
 |
| Ultra-Low
Back Scatter |
|
Enables
true zero setting to ensure accurate and reliable results below 0.1 NTU. |
 |
 |
 |
| Dry Secondary
Calibration Standard |
|
Simplifies
accurate and repeatable calibration and eliminates the need and cost of
chemical standards. |
 |
 |
 |
| Auto-Cleaning
Systems |
|
Maintains
superb performance and reduces maintenance by a programmable wiper cleaning
system. |
 |
 |
 |
| Lifetime
Zero |
|
Ensures
high accuracy, minimum maintenance and long-term performance. |
 |
 |
 |
| Wide
Analysis Range |
|
Programmed
to read out in either NTU or FTU from 0-5 NTU to 0-1000 FTU. Ideal for applications
varying from final treatment of potable water to effluent discharge monitoring. |
 |
 |
 |
| Advanced
Photodiode Technology |
|
Extremely
low noise signal enabling high accuracy and resolution to 0.01 NTU. Essential
for accurate results below 1.0 NTU. |
 |
 |
 |
| |
|
|
| GENERAL
SPECIFICATIONS |
| |
|
|
DISPLAY
Measured value:
5-digit x 7-segment backlit LCD
Information:
16-character, single line, dot matrix, backlit LCD
Ranges:
Used with 7997-10 1 0 - Z to 0 - 30 NTU
Used with 7997-201 0 - 50 to 0 - 250 NTU
Used with 7997-301 0 - 100 to 0 - 500 FLU and 0 - 1000 mg/I
Used with 7997-401 0 - 100 to O - 1000 FTU and 0 - 2000 mg/l
Units of measurement:
NTU and FTU all models mg/l on models 7997-301 and 7997-401
Accuracy:
=0.2% F.s.d., ±1 digit
Linearity:
t0.1 % f.s.d.
Auto-clean timing:
Programmable 15 min, 30 min, 45 min or 1 hour up to 24 hours in I hour increment
ENVIRONMENTAL DATA
Operating temperature limits:
200 to 550 C (-4° to 131 0 F)
Storage temperature limits:
250 to 55° C (-130 to 131 ° F)
Operating humidity limits:
Up to 95% RH non-condensing
POWER SUPPLY
Voltage requirements:
100 to 130V, 200 to 260V, 50/60Fiz
Power consumption:
<bVA a.c.
Error due to power supply variation:
Less than 0.1 % for +6% to -20% variation from nominal supply
Insulation:
Line to ground 2kV r.m.s.
|
|
RELAY
OUTPUTS AND SET POINTS
No. of relays:
Two
Relay contacts:
Single pole changeover
Rating 250V a.c., 250V d.c. max.
3Aa.c.
3Ad.c. max.
Loading (non-inductive) 750VA 30W max.
(inductive)
750VA 3W max.
Insulation:
2kV r.m.s. contacts ground
No. of set points:
Two
Set point adjustment:
Programmable
Set point hysteresis:
-1 % fixed
Local set point annunciation:
Red L. E. D.
RETRANSMISSION
No. of retransmission signals:
One fully isolated programmable 0 - 1 OmA, 0 - 20mA or 4 - 20mA
Accuracy:
10.25% f.s.d. -0.5% reading
Resolution:
0.1 % at I OmA, 0.05% at 20mA
Max. load resistance 75052 (20mA max.)
|
| MECHANICAL
DATA |
| |
Model 4670 |
Model 4675 |
| Mounting |
wall mounting |
panel mounting |
| Protection |
IP65 |
IP66 front |
| Weight |
4.5Ibs |
3.25Ibs |
| Dimensions |
(6.30 in)
wide |
(3.78 in)
wide |
| |
(8.43 in)
high |
(3.78 in)
high |
| |
(2.68 in/
deep |
(7.52 in)